ACE Weekly Report: 04-11-01 All ACE spacecraft subsystems are performing nominally. An attitude maneuver was performed on 04-10-01. The next attitude maneuver is scheduled for 04-16-01. Maneuver Start Time=17:44:35 Maneuver End Time=17:51:39 Pre-Maneuver HGA = -3.9 deg. Sun Angle = 8.95 deg. Post-Maneuver HGA = 4.4 deg. Sun Angle = 6.525 deg. Current S/C range: 1417728.465 km OCR ULEIS-037 was executed on 4-09-01 to return the ULEIS shutter to the 100% position. The shutter had been closed to the 6% position on 04-03-01 to avoid saturation during the recent solar flare. March Data Recovery Statistics: 99.992% Anomalies: G01-0028: ACE experienced an approximate two minute telemetry dropout due to 'Antenna stopping unexpectedly' on 04-06-01. Telemetry returned and no further problems were experienced. All affected SSR slices were redumped (DR# L05169). S01-0003: ULEIS Shutter Anomaly - The ULEIS shutter failed to close to the 6% position when OCR ULEIS-036 was executed on 4-10-01. The Instrument PI was notified and monitored the re-execution of OCR ULEIS-036. A shutter motor error occurred and the shutter failed to close to the directed 6% position. OCR ULEIS-038 was submitted and executed to clear the motor error and to attempt to close the shutter for a third time. The motor error occurred again. The Instrument team decided to leave the shutter open at the 100% position and analyze their data regarding the anomaly overnight. After checking their software code, the instrument team determined that there was an "error in a software table which tells the s/w where the center of 100%". A temporary workaround to this problem will allow ULEIS shutter to move to the "6% position by using lower level commands that will bypass the motor test which is where the error was occurring". OCR ULEIS-039 was executed on 4-11-01 to close the shutter to the 6% position using the lower level command. The instrument team is investigating the option of uplinking a memory load to correct the value in the s/w table. This activity is TBD. S01-0004: ULEIS Shutter Motor Error - During execution of OCR ULEIS-039 on 4-11-01, the shutter motor error flag was set unexpectedly. However the shutter did close to the commanded 6% position. The instrument team investigated and determined "that the software command that moves the shutter by specifying the number of motor steps to take DOES execute the motor motion test routine. Just as we experienced yesterday (4-10-01), executing this routine sometimes causes the motor error flag to be set. The difference with the motor stepping command, /ULEIS_MOVE_MOTOR, that was sent today (4-11-01), is that it ignores the occurrence of this error and moves the shutter anyway. The higher level commands sent [on 4-10-01] (e.g. /ULEIS_MOV_TO_POS) do not continue to move the shutter if the motor motion test fails. Hence, everything is fine with the shutter, other than the bug which was described yesterday which we need to fix."